车用永磁同步电机齿槽转矩抑制分析
管健晖,周伟强,胡军峰,赵玉婷,张艳,林霄喆
无锡星驱动力科技有限公司,江苏 无锡 214000
摘要:为降低齿槽转矩对电机噪声、振动与声振粗糙度(noise vibration harshness,NVH)性能及电机效率的不利影响,采用Motor-计算机辅助设计(computer aided design,CAD)建立电机的二维仿真模型,对定子槽深度、永磁体1厚度、永磁体2厚度、气隙等4项电机核心结构参数进行单指标分析,通过正交试验得出最佳结构参数组合,作为电机优化方案,并对原电机、优化后电机进行对比分析。结果表明:定子槽深度为14.13 mm、永磁体1厚度为1.05 mm、永磁体2厚度为1.10 mm、气隙为1.00 mm是最佳电机方案;对比原电机,优化后电机工作效率提高约0.3%,转矩脉动下降约4.493 N·m,最大齿槽转矩下降约0.217 N·m。优化后电机可有效抑制转矩脉动,提高电机工作效率。
关键词:永磁同步电机;齿槽转矩;Motor-CAD;正交试验
Analysis of cogging torque suppression for a vehicle permanent magnet synchronous motor
GUAN Jianhui, ZHOU Weiqiang, HU Junfeng, ZHAO Yuting,
ZHANG Yan, LIN Xiaozhe
Wuxi InfiMotion Propulsion Technology Co., Ltd., Wuxi 214000, China
Abstract: To mitigate the adverse effects of cogging torque on the noise, vibration and harshness (NVH) performance and efficiency of the motor, a two-dimensional simulation model of the motor is established via Motor-CAD. Single-factor analysis is performed on four key structural parameters of the motor, including stator slot depth, the thickness of the first permanent magnet, the thickness of the second permanent magnet and air gap. The orthogonal test method is adopted to obtain the optimal combination of structural parameters as the motor optimization scheme, and a comparative analysis between the original motor and the optimized motor is carried out. The results show that the optimal motor configuration is achieved with a stator slot depth of 14.13 mm, the first permanent magnet thickness of 1.05 mm, the second permanent magnet thickness of 1.10 mm and an air gap length of 1.00 mm. Compared with the original prototype motor, the operating efficiency of the optimized motor is improved by approximately 0.3%, the torque ripple is reduced by about 4.493 N·m, and the maximum cogging torque is decreased by roughly 0.217 N·m. The optimized motor can effectively suppress torque ripple and improve the operational efficiency of the motor.
Keywords: permanent magnet synchronous motor; cogging torque; Motor-CAD; orthogonal test