全预制部分包覆钢-混凝土桥墩轴心受压性能
楼纪昂1,赵晓华2,杜鑫蕾3,胡天乐3,查支祥4
1.浙江公路技师学院,浙江 杭州 310000;2.湖州立华路桥有限公司,浙江 湖州 313000;
3.河南科技大学土木建筑学院,河南 洛阳 471023;4.浙大宁波理工学院土木建筑工程学院,浙江 宁波 315100
摘要:为研究预制装配部分包覆钢-混凝土组合结构(precast partially encased composite,PPEC)在轴向荷载作用下的力学性能,设计3根分别采用腹板连接和不同螺栓间距的翼缘连接的PPEC柱和2根现浇部分包覆钢-混凝土组合结构(partially encased concrete,PEC),并进行轴压试验,分析对比其破坏模式、承载力、延性及应变发展规律。试验结果表明:腹板连接的PPEC柱耗能性能较好,但极限承载力小于现浇PEC柱;翼缘连接的PPEC柱中,螺栓间距为200 mm的试件极限承载力比现浇柱增大约20%,螺栓间距为250 mm的试件延性更优,承载力与现浇柱接近。所有试件均表现出良好的钢结构-混凝土协同工作性能和延性(位移延性系数均大于2.3),满足抗震设计要求。翼缘连接的PPEC柱尤其适用于桥梁桥墩等对承载力要求较高的场景,但需进一步优化螺栓间距平衡承载力与延性。
关键词:装配式施工;公路桥墩;静力试验
Axial compression behavior of fully prefabricated partially encased steel-concrete bridge piers
LOU Ji′ang1, ZHAO Xiaohua2, DU Xinlei3, HU Tianle3, ZHA Zhixiang4
1. Zhejiang Highway Technicians College, Hangzhou 310000, China;
2. Huzhou Lihua Road and Bridge Co., Ltd., Huzhou 313000, China;
3. School of Civil Engineering and Architecture, Henan University of Science and Technology, Luoyang 471023, China;
4. School of Civil Engineering and Construction, Ningbo Tech University, Ningbo 315100, China
Abstract: An experimental study on the mechanical performance of prefabricated partially encased composite (PPEC) columns under axial loading is presented. Through comparative axial compression tests on three PPEC columns (with web connections and flange connections featuring different bolt spacings) and two cast-in-place partially encased concrete(PEC) columns, the failure modes, load-bearing capacity, ductility, and strain development are systematically analyzed. Test results indicate that web-connected PPEC columns exhibit improves energy dissipation performance but lower ultimate load-bearing capacity compared to cast-in-place PEC columns; Among flange-connected PPEC columns, the specimen with a bolt spacing of 200 mm demonstrates approximately 20% higher ultimate load-bearing capacity than the cast-in-place column, while the specimen with a bolt spacing of 250 mm shows superior ductility and comparable load-bearing capacity to the cast-in-place column; All specimens exhibit favorable steel-concrete composite behavior and ductility (with displacement ductility coefficients exceeding 2.3), meeting seismic design requirements. The study demonstrates that flange-connected PPEC columns are particularly suitable for applications with high load-bearing demands, such as bridge piers engineering, though further optimization of bolt spacing is necessary to balance load-bearing capacity and ductility.
Keywords: prefabricated construction; highway bridge pier; static test